地暖的供回水温度在多少比较好?
来源:http://www.jndngs.com 日期:2020-01-07 发布人:admin
  地暖全称;低温地板辐射采暖系统,由热源供水,通过地热管循环加热散热至室、是目前的供暖方式。确保地暖正常工作有两大要素,一个是保证供回水温度,另外一个则是保证压力正常,那么地暖供水温度是多少,回水多少温度合适?下面济南地暖小编为您详细介绍地暖的供回水温度。
  Low temperature floor radiant heating system is the most comfortable heating mode at present, which is supplied by heat source and cooled to the room through geothermal pipe circulation. There are two factors to ensure the normal operation of the floor heating, one is to ensure the temperature of the water supply and return, the other is to ensure the pressure is normal, so what is the temperature of the water supply and return? Below Jinan floor heating small series for you to introduce the supply and return water temperature of floor heating in detail.
  地暖供水温度是多少?
  What is the temperature of ground heating water supply?
  通常地暖的供水水温要求在45℃-55℃左右,不宜超过60℃。
  Generally, the water temperature of the ground heating water supply should be about 45 ℃ - 55 ℃, and the maximum temperature should not exceed 60 ℃.
  地暖回水温度在35℃-45℃左右,保持与供水温度相差10度左右更合适?
  The temperature of the ground heating and return water is about 35 ℃ - 45 ℃, and it is the most appropriate to keep the difference between the temperature of the ground heating and the temperature of the water supply about 10 ℃?
  如果地暖供水温度超过60℃怎么办?
  What if the temperature of ground heating water supply exceeds 60 ℃?
济南地暖
  普通家庭做地暖当地暖供水温度超过60℃时可以采用混水装置来降低入户供水水温,工业采暖地暖供水温度超过60℃时可以采用大型混水缸来降低地暖供水温度。
  When the temperature of the floor heating water supply exceeds 60 ℃, the water mixing device can be used to reduce the water temperature of the household water supply. When the temperature of the industrial heating floor heating water supply exceeds 60 ℃, the large mixing tank can be used to reduce the temperature of the floor heating water supply.
  地暖供水温度超过更好限制60℃,一方面会影响地暖系统的舒适度,另外一方面会影响地暖管道将来的使用寿命。
  The ground heating water supply temperature exceeds the best limit of 60 ℃, on the one hand, it will affect the comfort of the ground heating system, on the other hand, it will affect the future service life of the ground heating pipeline.
  另外做地暖要注意地暖的供回水温差不宜大于10度,地暖管内热水流速:宜控制在 0.25-0.5m/s。
  In addition, the water temperature difference between the supply and return of the floor heating should not be greater than 10 degrees, and the flow rate of hot water in the floor heating pipe should be controlled within 0.25-0.5m/s.